Sine Control Technology has been producing effective Surge Protective Devices (also called Transient Voltage Surge Suppressors, or TVSS) for over 40 years.

Sine Control Powerclamp Series 2

In stock

Weight 3.6287 kg
features

40

,

000 Surge Amps Per Mode
2 Volt Clamping Level
1-2 Nanosecond Response Time
Parallel Wire-in Design 
High Energy Dissipation
Maintenance Free
Sine wave tracking
Simple Installation
Meets ANSI/IEEE C62-41 1980
Meets UL-1449-1994
Non-degrading
Passive System
Fault Indicating LEDs
Full Voltage Range
Voltage Reactive
5 Year Warranty

specification

TECHNICAL SPECIFICATIONS:
POWERCLAMP is a sophisticated surge suppression unit that offers the ultimate in transient protection

,

with ULTRA-LOW CLAMPING LEVELS. Its PARALLEL INSTALLATION provides these benefits:
• No chance of power interruption
• No need to match load power
• No insertion power loss
When tested to the ANSI/IEEE C62.41-1991/UL-1449 Standard

,

its hybrid multistage circuitry will suppress (clamp) transient surges and spikes in all modes and bi-directionally

,

as listed below.
Category A waveform (6kV

,

200amps

,

0.5us

,

100kHz): TWO (2) VOLTS of the peak of the sine wave.
Measured from the baseline at the 90º point of the power sine wave (@ WAVEFORM PEAK).
Category B ringwave (6kV

,

500amps

,

0.5us

,

100kHz): TEN (10) VOLTS of the peak of the sine wave.
Measured from the baseline at the 90º point of the power sine wave (@ WAVEFORM PEAK).
Category B impulse (6kV

,

1.2/50us

,

3

,

000 amps): THIRTY (30) VOLTS of the peak of the sine wave.
Measured from the baseline at the 90º point of the power sine wave (@ POSITIVE WAVEFORM PEAK).

 

Unit
Type
Max
Surge
Surge
Models of
Connection

Model
Service
RMS
Joules
Amps 20
Protection
Wiring

Number
40-420Hz
Voltage
Per Ø
microsec
 
 

*120VF2
120V 1Ø
0-135 L-N
672
40

,

000
L-N/L-G/N-G
1-L

,

1-N

,

1-G

1240VF2
120/240V 1Ø
0-135 L-N
672
40

,

000
L-L/L-N/L-G
2-L

,

1-G

*1240VF3
120/240V 1Ø
0-135 L-N
672
40

,

000
L-L/L-N/L-G/N-G
2-L

,

1-N

,

1-G

1208VF3
120/208V 3Ø WYE
0-135 L-N
672
40

,

000
L-L/L-N/L-G
3-L

,

1-G

*1208VF4
120/208V 3Ø WYE
0-135 L-N
672
40

,

000
L-L/L-N/L-G/N-G
3-L

,

1-N

,

1-G

240VF3
240V 3Ø DELTA
0-270 L-L
1400
40

,

000
L-L/L-G
3-L

,

1-G

L-L = line to line; L-N = line to neutral; L-G = line to ground; N-G = neutral to ground common mode*
*Common mode: Neutral to Ground

,

needed when not installed at main panel where Neutral and Ground are tied.

Ship Separately

0

Product can be split into multiple boxes

0

Sine Control PowerClamp Series 1

In stock

$ 495.86
Weight 2.268 kg
Product can be split into multiple boxes

0

Ship Separately

0

specification

Technical Specifications:

Response time:
1-2 nanoseconds

Maximum leakage current:
3mA

Minimum Humidity Range:
5% to 97%

Operating temperature:
-20ºC (-68º F) to 70º C (158º F) ambient temperature

Dimensions:
(plug-in unit) 4" wide

,

4" high

,

3" deep (wire-in unit) 4" wide

,

6" high. 3.5" deep

Shipping weight:
approximately 5 lbs. (including packaging)

features

FEATURES AND BENEFITS:

20

,

000 Surge Amps
Passive System
Non-degrading
Meets ANSI/IEEE C62-41 1980
2 Volt Clamping Level
Simple Installation
Meets UL-1449-1994
Wire-in Fault Indicating Light
Sine Wave tracking
Plug-in 6 ft. 15 amp cord
5 Year Warranty
1-2Nanosecond Response Time
Maintenance Free
Voltage Reactive
High Energy Dissipation
Plug-in Series/Parallel Design 

 

Henry Series 80 PowerClamp

In stock

Original price was: $ 1,650.92.Current price is: $ 1,569.25.
Weight 3.6287 kg
Product can be split into multiple boxes

0

Ship Separately

0

specification

Technical Specifications:

Response time:
1-2 nanoseconds

Maximum leakage current:
3mA

Fusing:
One fuse per phase with failure indicator lamps

Minimum Humidity Range:
5% to 97%

Operating temperature:
-20ºC (-68º F) to 70º C (158º F) ambient temperature

Dimensions:
(all units) 6" wide

,

6" high

,

4" deep

Shipping weight:
approximately 8 lbs. (including packaging)

features

FEATURES AND BENEFITS:

60

,

000 Surge Amps Per Mode
High Energy Dissipation
Meets ANSI/IEEE C62-41 1980 
Fault Indicating lamps
2 Volt Clamping Level
Maintenance Free
Meets UL-1449-1994
Full Voltage Range
1-2 Nanosecond Response Time
Sine wave tracking
Non-degrading
Voltage Reactive
Parallel Wire-in Design
Simple Installation
Passive System
5 Year Warranty

Sine Control PowerClamp Series 6

In stock

$ 1,782.76
Weight 3.6287 kg
Product can be split into multiple boxes

0

Ship Separately

0

specification

Technical Specifications:

Response time:
1-2 nanosecond

Maximum leakage current:
3mA

Fusing:
One fuse per phase with failure indicator lamps

Minimum Humidity Range:
5% to 97%

Operating temperature:
-20ºC (-68º F) to 70º C (158º F) ambient temperature

Dimensions:
8" wide

,

8" high

,

4" deep

,

(120/240V) 6" wide

,

6" high

,

4" deep

Shipping weight:
approximately 8 lbs. (including packaging)

features

FEATURES AND BENEFITS:

100

,

000 Surge Amps Per Mode
Sine Wave tracking
Non-degrading
Maintenance Free
Meets ANSI/IEEE C62-41 1980
Fault Indicating lamps
Meets UL-1449-1994
Full Voltage Range
1-2 Nanosecond Response Time
Voltage Reactive
2 Volt Clamping Level
5 Year Warranty
Parallel Wire-in Design
Passive System
Simple Installation
High Energy Dissipation

Sine Control PowerClamp Series 8

In stock

$ 2,091.94
Weight 11.3398 kg
Product can be split into multiple boxes

0

Ship Separately

0

specification

Response time:
1-2 nanoseconds

Maximum leakage current:
3mA

Fusing:
one fuse per phase with failure indicator lamps

Minimum Humidity Range:
5% to 97%

Operating temperature:
-20ºC (-68º F) to 70º C (158º F) ambient temperature

Dimensions:
10" wide

,

12" high

,

5" deep (120/240V) 8" wide

,

8" high

,

4" deep

Shipping weight:
approximately 25 lbs. (120/240V) 10 lbs. (including packaging)

features

FEATURES AND BENEFITS: 

150

,

000 Surge Amps Per Mode
Sine Wave tracking
Non-degrading
Maintenance Free
Meets ANSI/IEEE C62-41 1980
Fault Indicating lamps
Meets UL-1449-1994 
Full Voltage Range
1-2 Nanosecond Response Time
Voltage Reactive
2 Volt Clamping Level
5 Year Warranty
Parallel Wire-in Design
Passive System
Simple Installation
High Energy Dissipation

Sine Control PowerClamp Series 10

In stock

$ 3,494.34
Weight 11.3398 kg
Product can be split into multiple boxes

0

Ship Separately

0

specification

Technical Specifications:

Response time:
1-2 nanoseconds

Maximum leakage current:
3mA

Fusing:
one fuse per phase with failure indicator lamps

Minimum Humidity Range:
5% to 97%

Operating temperature:
-20ºC (-68º F) to 70º C (158º F) ambient temperature

Dimensions:
10" wide

,

12" high

,

5" deep (120/240V) 8" wide

,

8" high

,

4" deep

Shipping weight:
approximately 25 lbs. (120/240V) 10 lbs. (including packaging)

features

FEATURES AND BENEFITS:

200

,

000 Surge Amps Per Mode
Sine Wave tracking
Non-degrading
Maintenance Free 
Meets ANSI/IEEE C62-41 1980
Fault Indicating lamps
Meets UL-1449-1994
Full Voltage Range
1-2 Nanosecond Response Time
Voltage Reactive
2 Volt Clamping Level 
5 Year Warranty 
Parallel Wire-in Design
Passive System
Simple Installation 
High Energy Dissipation